Remove the factory-installed jumper from the emergency input terminal. Connect a Normally Closed (NC) volt-free contact from the building fire panel. Opening this circuit drops all hold-voltage, allowing the glass wings to open instantly for evacuation. 5. Mounting the Glass Wings
Torque the glass clamp bolts progressively using a calibrated torque wrench to the exact rating specified in your component kit (do not overtighten, as this can shatter the glass). 4. Electrical and Control Wiring
The is a flap-leaf speed gate with a transparent design, offering effective barrier performance in a small physical footprint. It is ideal for limited spaces such as office lobbies, government buildings, banks, retail, and educational facilities. The system is designed for quiet, smooth operation and is available in two standard finishes:
Gunnebo SpeedStile FL Installation Manual: The Complete Guide